Sprite icons
Logo Sentera
Sentera – your partner in HVAC control solutions
Category
Motor type
3 x 400 VAC / 50-60 Hz, Induction, class F/H
Motor power E, FI
3 x 400 VAC, 4 kW, 9,5 A
Motor control type
Frequency inverters
Functional variable
Temperature

Supply and Exhaust Air Handling Unit


Solutions to manage dual air handling units. Explore our cutting-edge control systems that seamlessly manage both supply and exhaust air flows, including heat recovery AHUs.
2 item(s) in 1 page(s)
Solution code
Title
Description

NOT FOR SALE YET - Temperature control | AC fans | rotary recuperator

Sophisticated temperature-based control system for supply and exhaust air handling unit. This solution includes two AC motors with 3-phase 400 V power supply and maximum current of 9,5 A per motor. Paired with advanced frequency inverters, these motors deliver control precision and efficiency. The 3-phase 400 V power supply motor of rotary recuperator is also controlled by frequency inverter with a maximum current of 2,2 A. Controlled AHU is equipped with water heater, featuring a pump and a modulating 3-way valve. This combination enables precise temperature regulation and unparalleled comfort. Notably, our comprehensive frost protection system provides dual-level safeguards, ensuring uninterrupted operation even in the harshest conditions. Our solution integrates a freon cooler and an AC outdoor unit. This solution provides the user with effortless management of the supply and exhaust dampers.
 
plus sign minus sign Articles Articles
Sentera Central Processing Unit series, on DIN rail with IP20.
DIN rail Power over Modbus supply module 24 VDC / 40 VA, supply voltage: 85-264 VAC / 50-60 Hz, output voltage: 24 VDC / 40 VA, Imax: 1,8 A.
DIN rail Modbus distribution box with 10 RJ45 and 12 RJ12 sockets.
Internet Gateway in IP20 DIN Rail enclosure, supply voltage: 24 VDC PoM (Power over Modbus), RTU Modbus communication with master/slave channel, integrated Ethernet LAN and WiFi-connection, version: 2.
Multifunctional outdoor sensor: T and rH, supply voltage: 24 VDC (PoM), selectable T and rH ranges, integrated ambient light sensor, Modbus RTU communication.
Duct temperature, relative humidity transmitter, supply voltage: 24 VDC (PoM), selectable T and rH ranges, Modbus RTU communication.
Digital temperature sensor for pipes, supply voltage: 24 VDC over RJ45 connector, Modbus RTU.
2-stage relay module in DIN Rail enclosure, 2 x C/O contacts: 5 A / 250 VAC, supply voltage: 24 VDC (PoM) and Modbus RTU communication, IP30.
Dual room temperature, relative humidity sensor, supply voltage: 24 VDC (PoM), selectable T, rH ranges, integrated ambient light sensor, Modbus RTU communication.
Duct temperature, relative humidity transmitter, supply voltage: 24 VDC (PoM), selectable T and rH ranges, Modbus RTU communication.
Differential pressure transmitter, range: 0-1.000 Pa, integrated K-factor, Modbus RTU and Power over Modbus (PoM) interface, supply voltage: 24 VDC.
Differential pressure transmitter, range: 0-1.000 Pa, integrated K-factor, Modbus RTU and Power over Modbus (PoM) interface, supply voltage: 24 VDC.
Dual differential pressure transmitter (high resolution), range: 0-1.000 Pa, integrated K-factor, analogue / modulating output: 0-10 VDC / 0-20 mA / PWM, Modbus RTU communication, supply voltage: 18-34 VDC / 15-24 VAC ± 10 %.
Frequency inverter, IP20, IN: 3 ph., OUT: 3 ph., 380-480 VAC, 9.5 A, 4.0 kW, Internal EMC Filter, ODE-3-240095-3F42.
Frequency inverter, IP20, IN: 3 ph., OUT: 3 ph., 380-480 VAC, 9.5 A, 4.0 kW, Internal EMC Filter, ODE-3-240095-3F42.
Frequency inverter, IP20, IN: 3 ph., OUT: 3 ph., 380-480 VAC, 2,2 A, 0.75 kW, Internal EMC Filter, ODE-3-140022-3F12.
Modbus RTU (RS485) adapter, communication between Sentera standard RJ45 and frequency inverter (FI-E, FISE).
Differential pressure connection set PVC.
All weather protection for outdoor sensors.
Current stock 1 U.
Factory lead time 3 Week(s)

NOT FOR SALE YET - Temperature control | AC fans | plate recuperator

Advanced temperature-based control system for dual air handling unit. The unit is equipped with a plate recuperator, complete with a damper-controlled bypass. Additionally, it includes water heater with a pump and a 3-way valve for temperature control. This unit includes a water cooler with a 3-way valve and chiller. This solution features two fans with AC 3-phase 400 V motors and a maximum current of 9,5 A per motor. Comprehensive protection system safeguards against both air and water frost, ensuring uninterrupted operation even in extreme conditions. Complete command over the supply and exhaust dampers.
 
plus sign minus sign Articles Articles
Sentera Central Processing Unit series, on DIN rail with IP20.
DIN rail Power over Modbus supply module 24 VDC / 40 VA, supply voltage: 85-264 VAC / 50-60 Hz, output voltage: 24 VDC / 40 VA, Imax: 1,8 A.
DIN rail Modbus distribution box with 10 RJ45 and 12 RJ12 sockets.
Internet Gateway in IP20 DIN Rail enclosure, supply voltage: 24 VDC PoM (Power over Modbus), RTU Modbus communication with master/slave channel, integrated Ethernet LAN and WiFi-connection, version: 2.
Multifunctional outdoor sensor: T and rH, supply voltage: 24 VDC (PoM), selectable T and rH ranges, integrated ambient light sensor, Modbus RTU communication.
Duct temperature, relative humidity transmitter, supply voltage: 24 VDC (PoM), selectable T and rH ranges, Modbus RTU communication.
Digital temperature sensor for pipes, supply voltage: 24 VDC over RJ45 connector, Modbus RTU.
2-stage relay module in DIN Rail enclosure, 2 x C/O contacts: 5 A / 250 VAC, supply voltage: 24 VDC (PoM) and Modbus RTU communication, IP30.
Dual room temperature, relative humidity sensor, supply voltage: 24 VDC (PoM), selectable T, rH ranges, integrated ambient light sensor, Modbus RTU communication.
Duct temperature, relative humidity transmitter, supply voltage: 24 VDC (PoM), selectable T and rH ranges, Modbus RTU communication.
Differential pressure transmitter, range: 0-1.000 Pa, integrated K-factor, Modbus RTU and Power over Modbus (PoM) interface, supply voltage: 24 VDC.
Differential pressure transmitter, range: 0-1.000 Pa, integrated K-factor, Modbus RTU and Power over Modbus (PoM) interface, supply voltage: 24 VDC.
Dual differential pressure transmitter (high resolution), range: 0-1.000 Pa, integrated K-factor, analogue / modulating output: 0-10 VDC / 0-20 mA / PWM, Modbus RTU communication, supply voltage: 18-34 VDC / 15-24 VAC ± 10 %.
Frequency inverter, IP20, IN: 3 ph., OUT: 3 ph., 380-480 VAC, 9.5 A, 4.0 kW, Internal EMC Filter, ODE-3-240095-3F42.
Frequency inverter, IP20, IN: 3 ph., OUT: 3 ph., 380-480 VAC, 9.5 A, 4.0 kW, Internal EMC Filter, ODE-3-240095-3F42.
Modbus RTU (RS485) adapter, communication between Sentera standard RJ45 and frequency inverter (FI-E, FISE).
Differential pressure connection set PVC.
All weather protection for outdoor sensors.
Current stock 1 U.
Factory lead time 3 Week(s)
Website is not supported on Internet Explorer! Please use Chrome, Firefox, Edge or other browser.