Fan heater or cooler control
EC fan heater controller | Wi-Fi and LAN gateway
Industrial fan heater controller with cloud connection. EC fan speed is regulated manually or automatically. The higher the difference between the measured temperature value and the temperature setpoint, the higher the EC fan speed. The unregulated output controls a water valve or an electric heating element. Via the separate internet gateway connection with SenteraWeb is possible. SenteraWeb is the online cloud platform for monitoring, data logging, remote access, day-week scheduler, etc. The controller can be connected via the local Wi-Fi network or via the LAN gateway.
EC fan heater controller | Wi-Fi gateway
Industrial fan heater controller with cloud connection. EC fan speed is regulated manually or automatically. The higher the difference between the measured temperature value and the temperature setpoint, the higher the EC fan speed. The unregulated output controls a water valve or an electric heating element. Via the separate internet gateway connection with SenteraWeb is possible. SenteraWeb is the online cloud platform for monitoring, data logging, remote access, day-week scheduler, etc. The controller can be connected via the local Wi-Fi network.
EC fan heater and cooler controller
Industrial fan heater controller to heat warehouses or manufacturing plants. This controller regulates fan speed and controls an external water valve. The higher the difference between the measured temperature value and the temperature setpoint, the higher the EC fan speed. The unregulated output controls a water valve or an electric heating element. All parameters can be adjusted via Modbus RTU communication.
Heater controller | AC motor 2,5 A
5-speed controller for fan heaters with single phase motor. The maximum motor current is 2,5 A. AC fan speed is regulated manually or automatically. When the temperature drops below the set point, the hot water valve is opened via the unregulated output. This unregulated output can control a water valve or an electric heating element. Ambient temperature is measured. The higher the difference between the measured temperature value and the temperature setpoint, the higher AC fan speed. The fan speed is controlled in 5-steps.
Heater controller | AC motor 5 A
5-speed controller for fan heaters with single phase motor. The maximum motor current is 5 A. AC fan speed is regulated manually or automatically. When the temperature drops below the set point, the hot water valve is opened via the unregulated output. This unregulated output can control a water valve or an electric heating element. Ambient temperature is measured. The higher the difference between the measured temperature value and the temperature setpoint, the higher AC fan speed. The fan speed is controlled in 5-steps.