Typical HVAC applications
Control solutions for typical HVAC applications.
Show filters
Hide filters
Filtered result
Destratification | EC fans | IP54
The air layers are mixed using ceiling fans with EC motors. The controller can directly control EC motors via an analogue output signal, with 0–10 V as the default analogue output type. It measures the temperature near the floor and ceiling using PT500 sensors and adjusts the ceiling fans accordingly to optimise the destratification process.
Articles
De-stratification controller: 2 x temperature inputs: PT500, 1 x analogue outputs: (0-10 VDC/0-20 mA/PWM), 1 x relay outputs: NO, Imax: 2 A, Modbus RTU communication
Passive room temperature sensor, PT 500 Ω, 3-pole terminal block 1,5 mm² connector.
Current stock 8 U
Factory lead time 4 Week(s)
Article has been added to your shopping cart.
Destratification | AC fans | 1.5A | IP54
Air mixing is achieved using ceiling fans with AC motors, with a maximum current of 1.5 A. The destratification controller uses PT500 sensors to measure the temperature at floor and ceiling level. Based on these measurements, it sends a 0–10 V analogue output signal to the AC motor fan speed controller, which adjusts the ceiling fan speed accordingly to optimise air mixing and destratification
Articles
De-stratification controller: 2 x temperature inputs: PT500, 1 x analogue outputs: (0-10 VDC/0-20 mA/PWM), 1 x relay outputs: NO, Imax: 2 A, Modbus RTU communication
Fan speed controller (electronic, triac), supply voltage: 230 VAC ±10 % / 50-60 Hz, Imax: 1,5 A, 0-10 VDC / 0-20 mA or 10-0 VDC / 20-0 mA analog input, Vmax / Vmin / Off level adjustable, Modbus RTU communication, IP54.
Passive room temperature sensor, PT 500 Ω, 3-pole terminal block 1,5 mm² connector.
Current stock 4 U
Factory lead time 5 Day(s)
Article has been added to your shopping cart.
Destratification | AC fans | 3 A | IP54
Air mixing is achieved using ceiling fans with AC motors, with a maximum current of 3 A. The destratification controller uses PT500 sensors to measure the temperature at floor and ceiling level. Based on these measurements, it sends a 0–10 V analogue output signal to the AC motor fan speed controller, which adjusts the ceiling fan speed accordingly to optimise air mixing and destratification
Articles
De-stratification controller: 2 x temperature inputs: PT500, 1 x analogue outputs: (0-10 VDC/0-20 mA/PWM), 1 x relay outputs: NO, Imax: 2 A, Modbus RTU communication
Fan speed controller (electronic, triac), supply voltage: 230 VAC ±10 % / 50-60 Hz, Imax: 3 A, 0-10 VDC / 0-20 mA or 10-0 VDC / 20-0 mA analog input, Vmax / Vmin / Off level adjustable, Modbus RTU communication, IP54.
Passive room temperature sensor, PT 500 Ω, 3-pole terminal block 1,5 mm² connector.
Current stock 8 U
Factory lead time 4 Week(s)
Article has been added to your shopping cart.
Destratification | AC fans | 6 A | IP54
Air mixing is achieved using ceiling fans with AC motors, with a maximum current of 6 A. The destratification controller uses PT500 sensors to measure the temperature at floor and ceiling level. Based on these measurements, it sends a 0–10 V analogue output signal to the AC motor fan speed controller, which adjusts the ceiling fan speed accordingly to optimise air mixing and destratification
Articles
De-stratification controller: 2 x temperature inputs: PT500, 1 x analogue outputs: (0-10 VDC/0-20 mA/PWM), 1 x relay outputs: NO, Imax: 2 A, Modbus RTU communication
Fan speed controller (electronic, triac), supply voltage: 230 VAC ±10 % / 50-60 Hz, Imax: 6 A, 0-10 VDC / 0-20 mA or 10-0 VDC / 20-0 mA analog input, Vmax / Vmin / Off level adjustable, Modbus RTU communication, IP54.
Passive room temperature sensor, PT 500 Ω, 3-pole terminal block 1,5 mm² connector.
Current stock 8 U
Factory lead time 5 Day(s)
Article has been added to your shopping cart.
Destratification | AC fans | 10 A | IP54
Air mixing is achieved using ceiling fans with AC motors, with a maximum current of 10 A. The destratification controller uses PT500 sensors to measure the temperature at floor and ceiling level. Based on these measurements, it sends a 0–10 V analogue output signal to the AC motor fan speed controller, which adjusts the ceiling fan speed accordingly to optimise air mixing and destratification
Articles
De-stratification controller: 2 x temperature inputs: PT500, 1 x analogue outputs: (0-10 VDC/0-20 mA/PWM), 1 x relay outputs: NO, Imax: 2 A, Modbus RTU communication
Fan speed controller (electronic, triac), supply voltage: 230 VAC ±10 %/ 50-60 Hz, Imax: 10 A, 0-10 VDC / 0-20 mA or 10-0 VDC / 20-0 mA analog input, Vmax / Vmin / Off level adjustable, Modbus RTU communication, IP54.
Passive room temperature sensor, PT 500 Ω, 3-pole terminal block 1,5 mm² connector.
Current stock 8 U
Factory lead time 4 Week(s)
Article has been added to your shopping cart.