Motor type
120 VAC / 60 Hz, Voltage controllable, class B
230 VAC / 50-60 Hz, Voltage controllable, class B
230 VAC / 50-60 Hz, Voltage controllable, class F
230 VAC / 50-60 Hz, Induction, class F/H
230 VAC / 50-60 Hz, Electronically commutating (EC)
3 x 230 VAC / 50-60 Hz, Induction, class F/H
3 x 400 VAC / 50-60 Hz, Voltage controllable, class B
3 x 400 VAC / 50-60 Hz, Induction, class F/H
3 x 400 VAC / 50-60 Hz, Electronically commutating (EC)
Motor power E, FI
230 VAC, 370 W, 4,3 A
230 VAC, 750 W, 7 A
230 VAC, 1,1 kW, 10,5 A
3 x 230 VAC, 370 W, 2,3 A
3 x 230 VAC, 750 W, 4,3 A
3 x 230 VAC, 1,5 kW, 7,0 A
3 x 230 VAC, 2,2 kW, 10,5 A
3 x 230 VAC, 4 kW, 18 A
3 x 230 VAC, 5,5 kW, 24 A
3 x 230 VAC, 7,5 kW, 30 A
3 x 230 VAC, 11 kW, 46 A
3 x 230 VAC, 4 kW, 15,3A
3 x 400 VAC, 370 W, 1,2 A
3 x 400 VAC, 750 W, 2,2 A
3 x 400 VAC, 1,5 kW, 4,1 A
3 x 400 VAC, 2,2 kW, 5,8 A
3 x 400 VAC, 4 kW, 9,5 A
3 x 400 VAC, 5,5 kW, 14 A
3 x 400 VAC, 7,5 kW, 18 A
3 x 400 VAC, 11 kW, 24 A
3 x 400 VAC, 15 kW, 30 A
3 x 400 VAC, 18,5 kW, 39 A
3 x 400 VAC, 22 kW, 46 A
Motor control type
Analog signal: 0...10 VDC, 0...20 mA, PWM
Triac - Phase angle control
Autotransformer (5 steps)
AC chopping
Frequency inverters
Motor max. current
0,5 A
1,0 A
1,5 A
2,0 A
2,5 A
3,0 A
3,5 A
4,0 A
5,0 A
5,5 A
6,0 A
7,0 A
7,5 A
8,0 A
9,5 A
10 A
11 A
13 A
14 A
16 A
18 A
20 A
22 A
24 A
30 A
Motor protection
TK - motor protection
PTC - motor protection
Motor maintenance switch
Not applicable
IP Protection
IP 20
IP 44
IP 54
IP 66
Operation
Max to Min
Min to Max
Configurable

Remote fan speed control


Fan speed can be set manually via a separate potentiometer or control switch. The external potentiometer or switch can be installed nearby the fan speed controller or in a separate room. Via this separate potentiometer or switch, the requested fan speed is sent to the AC fan speed controller or to the EC fan.
365 item(s) in 37 page(s)
Solution code
Title
Description

Induction motor 400 V | remote control | 4,1 A | 1,5 kW | IP20

Variable speed control for 3-phase 400 Volt motors. The maximum motor current is 4,1 A. The fan speed can be manually set via the remote potentiometer. At OFF position, the motor stops (the potentiometer output value is 0 % by default). The frequency inverter disables the motor in case motor overheating is detected via the motor ptc or thermal contacts. The supply voltage is 3-phase 400 Volt.
 
plus sign minus sign Articles Articles
Frequency inverter, IP20, IN: 3 ph., OUT: 3 ph., 380-480 VAC, 4.1 A, 1.5 kW, Internal EMC Filter, ODE-3-140041-3F12.
Potentiometer, supply voltage: 24 VDC PoM, Modbus RTU communication, output: voltage, current or PWM, infinitely from min (0-7 VDC/0-14 mA/0-70 % PWM) to max (7,5-10 VDC/15-20 mA/75-100 % PWM) or vice versa, OFF-position, flush/surface mounting IP44/54.
Current stock 1 U.
Factory lead time 3 Week(s)

Induction motor 400 V | remote control | 2,2 A | 0,75 kW | IP20

Variable speed control for 3-phase 400 Volt motors. The maximum motor current is 2,2 A. The fan speed can be manually set via the remote potentiometer. At OFF position, the motor stops (the potentiometer output value is 0 % by default). The frequency inverter disables the motor in case motor overheating is detected via the motor ptc or thermal contacts. The supply voltage is 3-phase 400 Volt.
 
plus sign minus sign Articles Articles
Frequency inverter, IP20, IN: 3 ph., OUT: 3 ph., 380-480 VAC, 2,2 A, 0.75 kW, Internal EMC Filter, ODE-3-140022-3F12.
Potentiometer, supply voltage: 24 VDC PoM, Modbus RTU communication, output: voltage, current or PWM, infinitely from min (0-7 VDC/0-14 mA/0-70 % PWM) to max (7,5-10 VDC/15-20 mA/75-100 % PWM) or vice versa, OFF-position, flush/surface mounting IP44/54.
Current stock 5 U.
Factory lead time 3 Week(s)

Induction motor 400 V | remote control | 5,8 A | 2,2 kW | IP20

Variable speed control for 3-phase 400 Volt motors. The maximum motor current is 5,8 A. The fan speed can be manually set via the remote potentiometer. At OFF position, the motor stops (the potentiometer output value is 0 % by default). The frequency inverter disables the motor in case motor overheating is detected via the motor ptc or thermal contacts. The supply voltage is 3-phase 400 Volt.
 
plus sign minus sign Articles Articles
Frequency inverter, IP20, IN: 3 ph., OUT: 3 ph., 380-480 VAC, 5.8 A, 2.2 kW, Internal EMC Filter, ODE-3-240058-3F42.
Potentiometer, supply voltage: 24 VDC PoM, Modbus RTU communication, output: voltage, current or PWM, infinitely from min (0-7 VDC/0-14 mA/0-70 % PWM) to max (7,5-10 VDC/15-20 mA/75-100 % PWM) or vice versa, OFF-position, flush/surface mounting IP44/54.
Current stock 4 U.
Factory lead time 3 Week(s)

Induction motor 400 V | remote control | 14 A | 5,5 kW | IP20

Variable speed control for 3-phase 400 Volt motors. The maximum motor current is 14 A. The fan speed can be manually set via the remote potentiometer. At OFF position, the motor stops (the potentiometer output value is 0 % by default). The frequency inverter disables the motor in case motor overheating is detected via the motor ptc or thermal contacts. The supply voltage is 3-phase 400 Volt.
 
plus sign minus sign Articles Articles
Frequency inverter, IP20, IN: 3 ph., OUT: 3 ph., 380-480 VAC, 14 A, 5.5 kW, Internal EMC Filter, ODE-3-340140-3F42.
Potentiometer, supply voltage: 24 VDC PoM, Modbus RTU communication, output: voltage, current or PWM, infinitely from min (0-7 VDC/0-14 mA/0-70 % PWM) to max (7,5-10 VDC/15-20 mA/75-100 % PWM) or vice versa, OFF-position, flush/surface mounting IP44/54.
Current stock 1 U.
Factory lead time 3 Week(s)

Induction motor 400 V | remote control | 9,5 A | 4,0 kW | IP20

Variable speed control for 3-phase 400 Volt motors. The maximum motor current is 9,5 A. The fan speed can be manually set via the remote potentiometer. At OFF position, the motor stops (the potentiometer output value is 0 % by default). The frequency inverter disables the motor in case motor overheating is detected via the motor ptc or thermal contacts. The supply voltage is 3-phase 400 Volt.
 
plus sign minus sign Articles Articles
Frequency inverter, IP20, IN: 3 ph., OUT: 3 ph., 380-480 VAC, 9.5 A, 4.0 kW, Internal EMC Filter, ODE-3-240095-3F42.
Potentiometer, supply voltage: 24 VDC PoM, Modbus RTU communication, output: voltage, current or PWM, infinitely from min (0-7 VDC/0-14 mA/0-70 % PWM) to max (7,5-10 VDC/15-20 mA/75-100 % PWM) or vice versa, OFF-position, flush/surface mounting IP44/54.
Current stock 5 U.
Factory lead time 3 Week(s)

Induction motor 3ph 230 V | remote control | 10,5 A | 2,2 kW | IP66

Variable speed control for 3-phase 230 Volt motors. The maximum motor current is 10,5 A. The fan speed can be manually set via the remote potentiometer. At OFF position, the motor stops (the potentiometer output value is 0 % by default). The frequency inverter disables the motor in case motor overheating is detected via the motor ptc or thermal contacts. The supply voltage is 3-phase 230 Volt. The frequency inverter has an IP66 protection against ingress of water and dirt.
 
plus sign minus sign Articles Articles
Frequency inverter, IP66, IN: 3 ph., OUT: 3 ph., 200-240 VAC, 10,5 A, 2.2 kW, Internal EMC Filter ODE-3-220105-3F4A.
Potentiometer, supply voltage: 24 VDC PoM, Modbus RTU communication, output: voltage, current or PWM, infinitely from min (0-7 VDC/0-14 mA/0-70 % PWM) to max (7,5-10 VDC/15-20 mA/75-100 % PWM) or vice versa, OFF-position, flush/surface mounting IP44/54.
Current stock 0 U.
Factory lead time 3 Week(s)

Induction motor 3ph 230 V | remote control | 7,0 A | 1,5 kW | IP66

Variable speed control for 3-phase 230 Volt motors. The maximum motor current is 7 A. The fan speed can be manually set via the remote potentiometer. At OFF position, the motor stops (the potentiometer output value is 0 % by default). The frequency inverter disables the motor in case motor overheating is detected via the motor ptc or thermal contacts. The supply voltage is 3-phase 230 Volt. The frequency inverter has an IP66 protection against ingress of water and dirt.
 
plus sign minus sign Articles Articles
Frequency inverter, IP66, IN: 3 ph., OUT: 3 ph., 200-240 VAC, 7.0 A, 1.5 kW, Internal EMC Filter ODE-3-220070-3F4A.
Potentiometer, supply voltage: 24 VDC PoM, Modbus RTU communication, output: voltage, current or PWM, infinitely from min (0-7 VDC/0-14 mA/0-70 % PWM) to max (7,5-10 VDC/15-20 mA/75-100 % PWM) or vice versa, OFF-position, flush/surface mounting IP44/54.
Current stock 0 U.
Factory lead time 3 Week(s)
Next arrival 12/01/2024 - 1 U.

Induction motor 3ph 230 V | remote control | 18 A | 4,0 kW | IP66

Variable speed control for 3-phase 230 Volt motors. The maximum motor current is 18 A. The fan speed can be manually set via the remote potentiometer. At OFF position, the motor stops (the potentiometer output value is 0 % by default). The frequency inverter disables the motor in case motor overheating is detected via the motor ptc or thermal contacts. The supply voltage is 3-phase 230 Volt. The frequency inverter has an IP66 protection against ingress of water and dirt.
 
plus sign minus sign Articles Articles
Frequency inverter, IP66, IN: 3 ph., OUT: 3 ph., 200-240 VAC, 18 A, 4.0 kW, Internal EMC Filter ODE-3-320180-3F4A.
Potentiometer, supply voltage: 24 VDC PoM, Modbus RTU communication, output: voltage, current or PWM, infinitely from min (0-7 VDC/0-14 mA/0-70 % PWM) to max (7,5-10 VDC/15-20 mA/75-100 % PWM) or vice versa, OFF-position, flush/surface mounting IP44/54.
Current stock 0 U.
Factory lead time 3 Week(s)

Induction motor 400 V | remote control | 1,2 A | 0,37 kW | IP20

Variable speed control for 3-phase 400 Volt motors. The maximum motor current is 1,2 A. The fan speed can be manually set via the remote potentiometer. At OFF position, the motor stops (the potentiometer output value is 0 % by default). The frequency inverter disables the motor in case motor overheating is detected via the motor ptc or thermal contacts. The supply voltage is 3-phase 400 Volt.
 
plus sign minus sign Articles Articles
Frequency inverter, IP20, IN: 3 ph., OUT: 3 ph., 380-480 VAC, 1,2 A, 0.37 kW, Internal EMC Filter, ODE-3-140012-3F12.
Potentiometer, supply voltage: 24 VDC PoM, Modbus RTU communication, output: voltage, current or PWM, infinitely from min (0-7 VDC/0-14 mA/0-70 % PWM) to max (7,5-10 VDC/15-20 mA/75-100 % PWM) or vice versa, OFF-position, flush/surface mounting IP44/54.
Current stock 0 U.
Factory lead time 3 Week(s)
Next arrival 13/01/2024 - 3 U.

Induction motor 3ph 230 V | remote control | 24 A | 5,5 kW | IP66

Variable speed control for 3-phase 230 Volt motors. The maximum motor current is 24 A. The fan speed can be manually set via the remote potentiometer. At OFF position, the motor stops (the potentiometer output value is 0 % by default). The frequency inverter disables the motor in case motor overheating is detected via the motor ptc or thermal contacts. The supply voltage is 3-phase 230 Volt. The frequency inverter has an IP66 protection against ingress of water and dirt.
 
plus sign minus sign Articles Articles
Frequency inverter, IP66, IN: 3 ph., OUT: 3 ph., 200-240 VAC, 24 A, 5,5 kW, Internal EMC Filter ODE-3-320240-3F4A.
Potentiometer, supply voltage: 24 VDC PoM, Modbus RTU communication, output: voltage, current or PWM, infinitely from min (0-7 VDC/0-14 mA/0-70 % PWM) to max (7,5-10 VDC/15-20 mA/75-100 % PWM) or vice versa, OFF-position, flush/surface mounting IP44/54.
Current stock 0 U.
Factory lead time 3 Week(s)
Website is not supported on Internet Explorer! Please use Chrome, Firefox, Edge or other browser.