TVOC controller | flush mounting | LED indicators | 24 V DC

Article code FCVCF-R
GTIN 0.540.100.300.627.6
Intrastat number 90.32.89.00
Category Room VOC controllers
Current stock 5 U.
Factory lead time 4 Week(s)

Product description

Temperature, relative humidity, air quality, and ambient light are all measured by this room sensor.

The unique enclosure allows for flush or surface mounting. The supply voltage is 24 V DC. Based on the measured values, the sensor algorithm controls the single analogue output. This single output can be used to control an EC fan, an AC fan speed controller, or a damper actuator directly. The output type is selectable and is set to 0-10 volts by default.

All measurements and output values are transmitted using Modbus RTU communication. The TVOC sensor element is replaceable. In many applications, the ambient light sensor can be used to control the ventilation system based on the occupancy of the room. Modbus RTU allows you to change all of the settings.

Additional specifications and description

Why should we measure VOC?
Measuring Volatile Organic Compounds (VOCs) in a room is important for assessing indoor air quality, as high levels of VOCs can be harmful to human health. VOCs are emitted from various sources such as paints, cleaning products, furniture, and more. Place the VOC monitor in the room you want to measure. It is important to position it where it can provide a representative sample of the air in the room. Avoid placing it too close to potential sources of VOCs (e.g. newly painted walls) or near windows or doors where outdoor air can influence measurements. Let the monitor run for some time to stabilise and provide accurate readings.

LED indication
The green, yellow, and red LEDs on this HVAC sensor controller provide a clear visual indication of the TVOC level. The green LED indicates that the TVOC level is within acceptable limits and that there is sufficient fresh air supply. The yellow LED illuminates when the TVOC level enters the alert range. The colour red indicates that the TVOC level is out of range or that there is insufficient fresh air supply. One of the other measured values (temperature or relative humidity) can also be indicated by the LED indicators. Modbus RTU provides access to the measured temperature, relative humidity, TVOC, dew point, and ambient light level. 
 
How to control fresh air supply?
The output of this sensor can directly control an EC fan, an AC fan speed controller or a damper actuator. The output value varies proportionally in function of the measured temperature, humidity and TVOC concentration. When more fresh air is required, the sensor will increase the fan speed or open the damper.
 
4-wire connection
The cage clamp terminal blocks shorten wiring and installation time. They eliminate the need for routine maintenance and ensure a reliable contact for solid or stranded wires. The supply voltage is 24 V DC. The power supply (V-) and output (GND) ground terminals are not connected internally. This means that a 4-wire cable is required to connect this sensor. Most 24 V DC power supplies have short-circuit, overload, and overvoltage protection. A 24 V DC supply voltage improves the safety and dependability of your installation. 
 
Flush mounting or surface mountingElectronic device in wall mounting box
This sensor is suitable for mounting on a wall, a flat surface, or in a standard European wall mounting box. When the sensor is flush mounted, only the front plate is visible on the wall.  
 
Easy to use
This sensor requires very little configuration. It is almost directly usable once it has been installed. Temperature and relative humidity are often region- and seasonal-specific. The presence of VOCs depends on the specific sources and activities taking place in a particular environment. These parameters are still adjusted to the correct values during installation. The other default settings will be suitable for most applications. However, they can also be adjusted via the respective Modbus registers if necessary. A different output type, for example, can be selected to make it compatible with other devices: 0-10 V DC; 0-20 mA; 0-100% PWM; Modbus RTU. The light levels of the LEDs used for status indication are adjustable and you can choose to deactivate one or more measurement values. The Modbus register map provides an exhaustive list of all programmable settings.  
 
The best quality and reliability
This HVAC sensor is manufactured in Europe. Each sensor is calibrated and tested in our factory. In the unlikely event of TVOC sensor element failure, this module can be replaced. We use sensor elements and components of high quality. This ensures the long-term stability and accuracy of this HVAC transmitter.

Remarks, reviews & ratings

06/11/2023
With the products of this company, I achieved a successful solution for management of air quality in a work room. Now I have the automation system, cleaner air and safe for people working in this room. The installing it was easy - both the installation part and the Internet web platform
Add a remark or a review and rating.
0
Report an error
For security reasons, your session is about to expire due inactivity.
Due prolonged inactivity, your session was automatically closed for security reasons. Please log in again.
Stay logged in Log in