Free cooling | AC fans | 6 A | IP54

No one has commented on this product yet, please be the first (look below), we appreciate your opinion!
Article code TA-F-000003
Current stock 0 U
Factory lead time 5 Day(s)

Solution description

Free cooling is achieved using exhaust and supply fans equipped with AC motors, with a maximum total current of 6 A. The free cooling controller uses PT500 sensors to measure both outdoor and indoor temperature. Based on these measurements, the controller generates a 0–10 V analogue output signal and sends it to the AC fan speed controller. The speed controller adjusts the rotational speed of the exhaust and supply fans, introducing cooler outdoor air into the room while removing warmer indoor air.

Additional specifications and description

How does free cooling work?
The free cooling controller uses two PT500 temperature sensors to measure indoor and outdoor temperatures and calculate the temperature difference. When the indoor temperature exceeds the configured setpoint and the temperature difference exceeds the adjustable threshold, free cooling is activated. The controller then regulates the ventilation fans to introduce cooler outdoor air and remove warmer indoor air, reducing the indoor temperature.

Can free cooling save energy? 
Why use energy-intensive air conditioning when cooler outdoor air can do the job? Free cooling uses the natural temperature difference between indoor and outdoor air to remove excess heat from a building. 
A dedicated controller monitors indoor and outdoor temperatures and automatically activates the ventilation fans when conditions are suitable for cooling. This reduces the need for air conditioning, lowers energy consumption and operating costs, and improves the energy efficiency of industrial buildings and warehouses. 

How are AC fans controlled?       
The free cooling controller sends an analogue control signal to the electronic AC fan speed controller, which adjusts the fan speed accordingly. 
This speed controller is designed for single-phase, voltage-controllable AC motors with a specified maximum current. It regulates the rotational speed by varying the voltage supplied to the motors.     

Which sensors should be used with the free cooling controller? 
The controller is designed to operate exclusively with PT500 sensors. Sentera offers several versions to meet different customer requirements. 
Depending on the application, the available options include sensors with a metal or plastic probe and various cable lengths, as well as room sensors for measuring indoor temperature.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     

Components of this solution

Article code
Quantity
Description

FCCA8-DM

1 U

Free cooling controller for industrial buildings and warehouses. The controller continuously monitors both indoor and outdoor temperatures and automatically determines when free cooling can be used. This method of cooling is more energy-efficient than air conditioning. Indoor and outdoor temperature are measured with two optional PT500 sensors. The free cooling activation point is adjustable. The analogue output controls fan speed, the relay output controls the fan inlet screen. All measured parameters, operating states, and configuration settings are accessible via Modbus RTU communication.

EVS-1-60-DM

1 U

The EVS-1-60-DM electronic speed controller is a sophisticated solution for automatic speed control of single-phase voltage-controllable motors (230 VAC / 50—60 Hz). Equipped with Modbus RTU communication, this unit offers remote control options, adjustable off level, and min. and max. output voltage settings. With a maximum current of 6 A, it provides time-limited motor operation initiated by logic or switch signals. The integrated ON-OFF switch and digital input enable versatile motor control. Precise adjustments are possible with internal trimmers and Modbus RTU.

FLTSN-P500P100

2 U

FLTSN-P500P100 is a passive sensor for measuring ambient temperature. The sensor uses a PT500 platinum element with a positive temperature coefficient of resistance and does not require a separate power supply. The length of the shielded cable is 1 m. The sensor element is enclosed in a plastic probe which provides an IP65 protection. The sensor is suitable for both indoor and outdoor HVAC applications.