Sprite icons

Duct TVOC controller, 24 VDC

No one has commented on this product yet, please be the first (look below), we appreciate your opinion!
Article code DCVCF-R
GTIN 0.540.100.301.809.5
Intrastat number 90.32.89.00
Category End of life approaching
Current stock 20 U.
Factory lead time 5 Week(s)

Product description

Duct air quality controller with single output. It measures temperature, relative humidity and air quality (TVOC). The supply voltage is 24 VDC. The sensor algorithm controls the single analogue output based on the measured values. This single output can be used to directly control an EC fan, an AC fan speed controller or a damper actuator. The default output is 0-10 V. The output type can be adjusted. All measurements and the output value are available via Modbus RTU communication. The TVOC sensor element is replaceable. All settings can be adjusted via Modbus RTU.

Additional specifications and description

  
Optimised for air ducts
This HVAC transmitter measures temperature, relative humidity and air quality in air ducts. Based on the temperature and humidity, the dew point is calculated. This sensor will function best if it is installed in a straight section of the air duct. Avoid installation in turbulent air zones nearby filters, fans, cooling coils, etc. Position the sensor correctly with respect to the airflow direction. Please consult the mounting instructions for more detailed information.
  
How does it work?
The sensor algorithm controls one output. This output can control an EC fan, an AC fan speed controller or a damper actuator. The output value varies proportionally in function of the measured temperature, relative humidity and TVOC level. E.g. as temperature, relative humidity or TVOC level approaches their maximum limit, fan speed will increase or the damper will open.
  
Easy to use!
This sensor doesn't require configuration. Once installed, it is ready to use. The default settings will do for most applicationsIf necessary, the settings can be adjusted via Modbus RTU. For example, a different output type can be selected to make it compatible with other devices: 0-10 VDC / 0-20 mA / 0-100 % PWM. The Modbus register map provides a complete overview of all adjustable settings.
  
4-wire connection
The supply voltage is 24 VDC. The ground terminals of the power supply (V-) and output (GND) are internally not connected. This means that a 4-wire cable is required to connect this sensor. Most 24 VDC power supplies offer protection against short circuit, overload and overvoltage. A 24 VDC supply voltage increases the safety and reliability of your installation.
  
High quality
Each sensor is calibrated and tested in our factory. In the unlikely event of TVOC sensor element failure, this module can be replaced. We use sensor elements and components of high quality. This ensures the long-term stability and accuracy of this HVAC transmitter. The enclosure offers an IP54 protection against ingress of dust and moisture. The sensor element is integrated in the probe of the duct sensor. This probe has an opening to have a direct contact between the air flow and the sensor element. The sensor probe offers an IP20 protection.      
 
 

Remarks, reviews & ratings

There are no reviews added yet. Please don't hesitate and be the first! We value your opinion.
Add a remark or a review and rating.
0
Report an error