Sprite icons

CO2 sensor | IP65 enclosure | PoM

No one has commented on this product yet, please be the first (look below), we appreciate your opinion!
Article code ODMFM-R
GTIN 14 5401003010679
Intrastat number 90.27.10.10
Category Outdoor CO2 sensors
Current stock 3 U.
Factory lead time 4 Week(s)

Product description

This CO2 sensor is designed for outdoor and harsh environment HVAC applications.

Measurement: It measures temperature, humidity, CO2, and ambient light; ranges are selectable.

Power & Communication: It operates on 24 V DC PoM (power and Modbus RTU from a single RJ45). All settings are done via Modbus RTU (RS485), and firmware is updatable.

Control & Flexibility: Manages ventilation with an ambient light sensor (adjustable active/standby levels).
A removable CO2 sensor element allows for easy calibration

Durability: Suitable for harsh environments.

Additional specifications and description

Why is CO2 Measurement Important in Harsh Environments, and What Parameters Does This Sensor Measure?
Measuring carbon dioxide (CO2) in harsh environments can be challenging, but it is crucial for various applications, including industrial processes, environmental monitoring, and safety assessments. Harsh environments may include high temperatures, high pressures, corrosive atmospheres, or remote and hard-to-reach locations.
People and animals produce CO2 or carbon dioxide while breathing. That makes CO2 concentration a good indicator for the occupancy and activity level in a space. In many applications, CO2 sensors are used as an indicator for the ventilation requirements. This HVAC transmitter measures temperature, relative humidity, CO2 and ambient light level. Based on the temperature and humidity measurement, the dew point is calculated. All these values are available via Modbus RTU. The enclosure is designed for harsh environments or outdoor applications.

Why Doesn't the Sensor Have Analog Outputs, and How is Data Read via Modbus?
This sensor does not have analogue outputs which makes it simpler and more cost efficient. All measured values are available via the Modbus input registers of this sensor. Reading the measured values is possible via SenteraWeb - our online HVAC platform, via 3SModbus software, via a BMS system or via another Modbus master device. Modbus has numerous advantages. The most important ones are that digital signals are less susceptible to interference than analogue signals and that longer cables can be used. Cable lengths of up to 1.000 meters are possible. 

 
How Does NDIR Technology Work in CO2 Measurement?
NDIR or Non-dispersive Infrared technology is used to measure the CO2 level. This technology offers a low life-cycle cost and a precise and stable long-term operation.
 
How are the Sensor's Power and Communication Connected, and What is Power over Modbus (PoM)?
This sensor can be connected with just one RJ45 connector. Power over Modbus (PoM) refers to the connection of Modbus RTU communication and a 24 V DC power supply via a single UTP cable. Modbus RTU communication makes all measured values available. To make wiring easier, we recommend using Sentera 24 V DC power supplies with RJ45 connectors. These power supplies provide short-circuit, overload, and overvoltage protection. A supply voltage of 24 V DC improves the safety and reliability of your installation. 
 
What are the Sensor's Installation and Customization Options?
This sensor requires very little configuration. Once installed, it is almost directly ready to use. Temperature and relative humidity are frequently region- and season-specific. These parameters are still set to the correct values during installation. The other default settings are likely to be adequate for most applications. They can, however, be adjusted using the respective Modbus registers if necessary. The Modbus register map provides a complete overview of all adjustable settings. 
 
How Does the ABC Logic Self-Calibration Algorithm Work?
The ABC logic self-calibrating algorithm is by default enabled. This algorithm is designed to be used in applications where CO2 concentrations will drop to outside ambient conditions (400 ppm) at least once (15 minutes) in a 7day period, which is typically seen during unoccupied periods. The sensor will reach its operational accuracy after 25 hours of continuous operation at a condition that it was exposed to ambient reference levels of air at 400 ppm ± 10 ppm CO2.
 
What Are the Protection Features of the Sensor Enclosure, and How Is It Protected Against Outdoor Conditions?
The enclosure offers an IP65 protection against ingress of dust and water. Each sensor is calibrated and tested in our factory. We use sensor elements and components of high quality. This ensures the long-term stability and accuracy of this HVAC transmitter. To ensure optimal performance, the sensor should be protected from direct sunlight. To protect this sensor from too bright sun, rain or snow, we have designed a special cover cap - AWP-10-13-13 - that fits perfectly over the sensor, further ensuring its proper functioning.